Principal contractor: Morgan Est

Design parameters

Number of Tanks12
Size of Each Tank41.4m x 26.7m x 6m
Volume of Each Tank6,636 m3
Number of Passes per Tank2
Number of Control Zones per Tank2
Total Number of Aquaconsult Diffusers3,000
Aquaconsult Diffusers per Tank250
Type and Length of DiffuserP4.0 EU, 4.0m long
Membrane TypePolyurethane
Download Our Product Sheet