Design Parameters

Number of Tanks6
Size of Each Tank62.3m x 24.6m x 6m
Volume of Each Tank9,198 m3
Number of Passes per Tank2
Number of Control Zones per Tank2
Total Number of Aquaconsult Diffusers1,620
Aquaconsult Diffusers per Tank270
Type and Length of DiffuserP3.5 EU, 3.5m long
Membrane TypePolyurethane